  • TRANSFORMER

    ABOUT PRODUCTS

    DRY TRANSFORMERS

    Our dry transformers use insulating paper with

    strong heat and moisture resistance,

    and are impregnated with high-quality varnish to

    reduce the risk of fire. Maintenance and

    inspection are simple and easy to handle.

    We produce and supply a variety of models,

    from small for operation to large capacity.

     (K.S, JEC, IEC, IEEE, CE, TUV, UL)

    LOW-VOLTAGE DRY TYPE TRANSFORMER

    PRODUCT SPECIFICATIONS

    Since oil is not used for insulation and cooling, and heat-resistant, high-temperature special coating and insulating paper are used and treated with special varnish, there is no risk of fire or explosion of the transformer, and its small and light appearance makes it easy to repair and inspect, and is used in ships, buildings, factories, Suitable for indoor use in tunnels, underground, power plants, and substations.

     Number of phase : 1Ø, 3Ø(3-2Ø, 3-6Ø)

     Rated Frequency : 60Hz, 50Hz

     Rated Capacity : 1kVA ~ 5MVA

     Standard : KS, JEC, IEC, IEEE etc.

     Primary voltage(Input Rated Voltage) : UP TO 600V

     secondary voltage(Output Rated Voltage) : 110, 220, 380, 440V etc.

     Insulation Level : Types A, E, B, F, H, C, N

     Connection : D D0, D YN11, D Y1, D YN5 etc.

    ※ The above dimensions may change slightly

    depending on the detailed specifications of the

    conductor (CU, AL).

    ※ Since it is manufactured according to our

    specifications, the above dimensions are for

    reference only. Please inquire separately.

    DRY TRANSFORMERS

    Our dry transformers use insulating paper with

    strong heat and moisture resistance,

    and are impregnated with high-quality varnish to

    reduce the risk of fire. Maintenance and

    inspection are simple and easy to handle.

    We produce and supply a variety of models,

    from small for operation to large capacity.

     (K.S, JEC, IEC, IEEE, CE, TUV, UL)

    HIGH-VOLTAGE DRY TYPE TRANSFORMER

    PRODUCT SPECIFICATION

    It has an excellent cooling effect, smooth expansion and contraction, and is highly durable at high voltages. It uses heat-resistant, high-temperature special coated insulating paper and is treated with a special varnish, so there is no risk of fire or explosion in the transformer.

    It is small and light, making it easy to repair and inspect. It is convenient and suitable for indoor use in ships, buildings, factories, tunnels, underground, power plants, and substations.

     Number of phase : 1Ø, 3Ø(3-2Ø, 3-6Ø)

     Rated Frequency : 60Hz, 50Hz

     Rated Capacity : 1kVA ~ 5MVA

     Standard : KS, JEC, IEC, IEEE etc.

     Primary voltage(Input Rated Voltage) : UP TO 600V

     Secondary voltage(Output Rated Voltage) : 110, 220, 380, 440V etc.

     Insulation Level : Types A, E, B, F, H, C, N

     Connection : D D0, D YN11, D Y1, D YN5 etc.

    ※ The above dimensions may change slightly

    depending on the detailed specifications of the

    conductor (CU, AL).

    ※ Since it is manufactured according to our

    specifications, the above dimensions are for

    reference only. Please inquire separately.

    NOISE CUT 

    TRANSFORMER

     Purpose of use

    Due to the concentration of advanced devices in digital technology, the various operating frequencies of electrical/electronic devices are

    combined with the fundamental frequency to block the spread of unnecessary electrical and electronic energy that interferes with the normal

    operation of the device.

     Usage

    For supply of production automation centralized system, broadcasting/audio transceiver, PLC, ROBOT control device, medical equipment, etc.

     Features

    1. As a basic transformer, it has good electrical characteristics and excellent insulation strength.

    2. Reduce noise by electromagnetic induction with multiple electrostatic shielding in transformer structure

    3. Prevention of capacity coupling and error coupling

     Product specifications

     Number of phase : 1phase, 3phase

     Rated Frequency : 60Hz, 50Hz

     Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

     Product photo

    SCOTT TRANSFORMER

     Purpose of use

    It is a transformer (Scott Connection Transformer)

    used by converting three-phase power into a single-

    phase large capacity load. It is a special transformer

    used to reduce three-phase imbalance that occurs

    when using a single-phase load.

     Usage

    It is used to resolve three-phase imbalance during

    single-phase large capacity loads in three-phase power

    sources such as AC electric railways, electric furnaces,

    charging storage devices, and ESS.

     Features

    1. As a basic transformer, it has good electrical

    characteristics and excellent dielectric strength.

    2. If both sets of single-phase power sources are

    equal, the three-phase load is balanced on the three-

    phase power side.

     Product specifications

     Number of phase : 1 phase, 3 phase

     Rated Frequency : 60Hz, 50Hz

     Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

     Product photo

    TRANSFORMER FOR

    ELECTRIC FURNACE

     Purpose of use

    It is a transformer that melts or heat-treats metal by

    supplying a large current to an electric furnace.

    As a harmonic resistance (K, F) transformer, it must

    be manufactured more specifically than a general

    transformer to be used for its intended purpose.

     Usage

    It is used for large capacity loads such as arc furnaces, melting furnaces, and heat treatment furnaces.

     Features

    1. As a special transformer, it has good electrical

    characteristics and excellent insulation strength.
    2. Special heat dissipation structure provides

    excellent cooling characteristics and excellent short-

    circuit mechanical strength.
    3. Harmonic tolerant K-Factor transformer.

     Product specifications

     Number of phase : 1phase, 3phase

     Rated Frequency : 60Hz, 50Hz

     Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

     Product photo

    MULTIPHASE TRANSFORMER

     Purpose of use

    The rectification constant of thyristor application equipment has 6 phases, and in the CVCF rectifier, the wiring of the rectifier transformer is both △ type and Y type, resulting in 12-phase rectification. It is mainly used for speed control of electric motors, so it is better than general transformers. It must be specially manufactured to be used for its intended purpose.

     Usage

    For communication, electrolysis, electroplating, DC motor power, charger, 6-phase rectification: Inverter (VVVF), 12-phase rectification: uninterruptible power supply (UPS), 24-phase rectification: Used in thyristor motors, etc.

     Features

    1. As a special transformer, it has good electrical characteristics and excellent insulation strength.

    2. The special heat dissipation structure provides excellent cooling characteristics and excellent short-circuit mechanical power.

    3. By phase - single phase (half wave, full wave), 3 phase, 6 phase, 12 phase, etc., it is a harmonic tolerance K-Factor transformer.

     Product specifications

     Number of phase : 3, 6, 12, 24 phase

     Rated Frequency : 60Hz, 50Hz

     Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

     Product photo

    TRANSFORMERS

    ABOUT PRODUCTS

    DRY TRANSFORMERS

    Our dry transformers use insulating paper with strong heat and moisture resistance, and are impregnated with

    high-quality varnish to reduce the risk of fire. Maintenance and inspection are simple and easy to handle.

    We produce and supply a variety of models, from small for operation to large capacity. (K.S, JEC, IEC, IEEE, CE, TUV, UL)

    LOW-VOLTAGE DRY TYPE TRANSFORMER

    PRODUCT SPECIFICATIONS

    Since oil is not used for insulation and cooling, and heat-resistant, high-temperature special coating and insulating paper are used and treated with special varnish, there is no risk of fire or explosion of the transformer, and its small and light appearance makes it easy to repair and inspect, and is used in ships, buildings, factories, Suitable for indoor use in tunnels, underground, power plants, and substations.

    Number of phase : 1Ø, 3Ø(3-2Ø, 3-6Ø)

    Rated Frequency : 60Hz, 50Hz

    Rated Capacity : 1kVA ~ 5MVA

    Standard : KS, JEC, IEC, IEEE etc.

     Primary voltage(Input Rated Voltage) : UP TO 600V

    secondary voltage(Output Rated Voltage) : 110, 220, 380, 440V etc.

    Insulation Level : Types A, E, B, F, H, C, N

    Connection : D D0, D YN11, D Y1, D YN5 etc.

    ※ The above dimensions may change slightly depending on the detailed specifications of the conductor (CU, AL).

    ※ Since it is manufactured according to our specifications, the above dimensions are for reference only. Please inquire separately.

    DRY TRANSFORMERS

    Our dry transformers use insulating paper with strong heat and moisture resistance, and are impregnated with

    high-quality varnish to reduce the risk of fire. Maintenance and inspection are simple and easy to handle.

    We produce and supply a variety of models, from small for operation to large capacity. (K.S, JEC, IEC, IEEE, CE, TUV, UL)

    HIGH-VOLTAGE DRY TYPE TRANSFORMER

    PRODUCT SPECIFICATIONS

    It has an excellent cooling effect, smooth expansion and contraction, and is highly durable at high voltages. It uses heat-resistant, high-temperature special coated insulating paper and is treated with a special varnish, so there is no risk of fire or explosion in the transformer.

    It is small and light, making it easy to repair and inspect. It is convenient and suitable for indoor use in ships, buildings, factories, tunnels, underground, power plants, and substations.

    Number of phase : 1Ø, 3Ø(3-2Ø, 3-6Ø)

    Rated Frequency : 60Hz, 50Hz

    Rated Capacity : 1kVA ~ 5MVA

    Standard : KS, JEC, IEC, IEEE etc.

     Primary voltage(Input Rated Voltage) : UP TO 600V

     Secondary voltage(Output Rated Voltage) : 110, 220, 380, 440V etc.

    Insulation Level : Types A, E, B, F, H, C, N

    Connection : D D0, D YN11, D Y1, Yy0, etc.

    ※ The above dimensions may change slightly depending on the detailed specifications of the conductor (CU, AL).

    ※ Since it is manufactured according to our specifications, the above dimensions are for reference only. Please inquire separately.

    NOISE CUT TRANSFORMERS

     Purpose of use

    Due to the concentration of advanced devices in digital technology, the various operating frequencies of electrical/electronic devices are

    combined with the fundamental frequency to block the spread of unnecessary electrical and electronic energy that interferes with the normal

    operation of the device.

     Usage

    For supply of production automation centralized system, broadcasting/audio transceiver, PLC, ROBOT control device,

    medical equipment, etc.

     Features

    1. As a basic transformer, it has good electrical characteristics and excellent insulation strength.

    2. Reduce noise by electromagnetic induction with multiple electrostatic shielding in transformer structure

    3. Prevention of capacity coupling and error coupling

     Product specifications

    Number of phase : 1phase, 3phase

    Rated Frequency : 60Hz, 50Hz

    Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

    SCOTT TRANSFORMER

     Purpose of use

    It is a transformer (Scott Connection Transformer) used by converting three-phase power into a single-phase large capacity load.

    It is a special transformer used to reduce three-phase imbalance that occurs when using a single-phase load.

     Usage

    It is used to resolve three-phase imbalance during single-phase large capacity loads in three-phase power sources such as

    AC electric railways, electric furnaces, charging storage devices, and ESS.

     Features

    1. As a basic transformer, it has good electrical characteristics and excellent dielectric strength.

    2. If both sets of single-phase power sources are equal, the three-phase load is balanced on the three-phase power side.

     Product specifications

    Number of phase : 1 phase , 3 phase

    Rated Frequency : 60Hz, 50Hz

    Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : Types A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

    TRANSFORMER FOR ELECTRIC FURNACE

     Purpose of use

    It is a transformer that melts or heat-treats metal by supplying a large current to an electric furnace.

    As a harmonic resistance (K, F) transformer, it must be manufactured more specifically than a general transformer to be used

    for its intended purpose..

     Usage

    It is used for large capacity loads such as arc furnaces, melting furnaces, and heat treatment furnaces.

     Features

    1. As a special transformer, it has good electrical characteristics and excellent insulation strength.

    2. Special heat dissipation structure provides excellent cooling characteristics and excellent short-circuit mechanical strength.

    3. Harmonic tolerant K-Factor transformer.

     제품규격/SPECIFICATION

    상수(Number of phase) : 1phase, 3phase

     주파수(Rated Frequency) : 60Hz, 50Hz

     정격용량(Rated Capacity) : 1~3000kVA

     주파수(Rated Voltage) : up to 7.2kV

     절연등급(Insulation Level) : A, E, B, F, H, C, N

     냉각방식(Cooling Method) : AN, ANAN, ONAN, FA

    MULTIPHASE TRANSFORMER

     Purpose of use

    The rectification constant of thyristor application equipment has 6 phases, and in the CVCF rectifier, the wiring of the rectifier transformer is

    both △ type and Y type, resulting in 12-phase rectification. It is mainly used for speed control of electric motors, so it is better than general

    transformers. It must be specially manufactured to be used for its intended purpose.

     Usage

    For communication, electrolysis, electroplating, DC motor power, charger, 6-phase rectification: Inverter (VVVF),

    12-phase rectification: uninterruptible power supply (UPS), 24-phase rectification: Used in thyristor motors, etc.

     Features

    1. As a special transformer, it has good electrical characteristics and excellent insulation strength.

    2. The special heat dissipation structure provides excellent cooling characteristics and excellent short-circuit mechanical power.

    3. By phase - single phase (half wave, full wave), 3 phase, 6 phase, 12 phase, etc., it is a harmonic tolerance K-Factor transformer.

     Product specifications

    Number of phase : 3, 6, 12, 24 phase

    Rated Frequency : 60Hz, 50Hz

    Rated Capacity : 1~3000kVA

     Rated Voltage : up to 7.2kV

     Insulation Level : Types A, E, B, F, H, C, N

     Cooling Method : AN, ANAN, ONAN, FA

    {"google":["Noto Sans"],"custom":["SCDream","Noto Sans KR"]}{"google":["Noto Sans","Open Sans"],"custom":["SCDream","Noto Sans KR","Tmon Monsori","Jeju Gothic"]}